Modifiche

Jump to navigation Jump to search
nessun oggetto della modifica
Riga 1: Riga 1: −
The results of the ink bottle capacities are summarized in the table maintained on this page. What we measure is not the total capacity of the bottle (which will be marked for reference) but the capacity to allow the pen to be filled leaving the lowest residue when the contents are exhausted.  
+
The results of the ink bottle capacities are summarized in the table maintained on this page. What we measure is not the total capacity of the bottle (which will be marked for reference) but the capacity to allow the pen to be filled leaving the lowest residue when the contents are exhausted. The purpose is to check how reliable the claim to fill "to the last drop" is.
    
==Measurement mode==
 
==Measurement mode==
 +
 +
{{Doppia immagine verticale|right|Pelikan-140-StripedGreen-Posted.jpg|Parker-Duofold-Cell-Sr-3V-PearlBlackStriated-Open.jpg|300|The pens used in measurements.}}
    
The measurement methods are described in [https://www.penciclopedia.it/6933/fino-allultima-goccia/ this article (in italian)] on the blog and discussed in [https://forum.fountainpen.it/viewtopic.php?f=12&t=20844 this topic (in italian)] on the forum, where the results of the various measurements are also explained. This page is mainly used to report the summary of the results, we will limit ourselves to a brief summary.
 
The measurement methods are described in [https://www.penciclopedia.it/6933/fino-allultima-goccia/ this article (in italian)] on the blog and discussed in [https://forum.fountainpen.it/viewtopic.php?f=12&t=20844 this topic (in italian)] on the forum, where the results of the various measurements are also explained. This page is mainly used to report the summary of the results, we will limit ourselves to a brief summary.
    
We used two pens (a [[Pelikan 140]] for medium to small size and a [[Duofold]] De Luxe for medium-large size) to progressively empty the bottle of ink or the inkwell under examination by repeatedly filling them. The four methods to fill the pen from the bottle defined in the following paragraph were used, weighing the remaining residue for each of them with centigram accuracy using a balance.
 
We used two pens (a [[Pelikan 140]] for medium to small size and a [[Duofold]] De Luxe for medium-large size) to progressively empty the bottle of ink or the inkwell under examination by repeatedly filling them. The four methods to fill the pen from the bottle defined in the following paragraph were used, weighing the remaining residue for each of them with centigram accuracy using a balance.
 +
 +
We regarded (apart from the last case) as the limit of passage between one filling mode and another the step in which, maintaining that mode, the pen cannot be filled in a significant way, assuming as "significant" the amount of 0.8 ml of ink, basically the content of a short cartridge.
    
==Definitions==
 
==Definitions==
   −
The table lists the capacities for four different filling modes:
+
The table lists the capacities for the four different filling modes:
    
* ''normal filling'': it is loaded with the bottle is placed horizontally in the ordinary position where it is also resting, inserting the pen from the mouthpiece without any shrewdness. This is the normal way to load a pen, the simplest and most convenient.
 
* ''normal filling'': it is loaded with the bottle is placed horizontally in the ordinary position where it is also resting, inserting the pen from the mouthpiece without any shrewdness. This is the normal way to load a pen, the simplest and most convenient.
Riga 18: Riga 22:  
== Results ==
 
== Results ==
   −
In the following table are listed only the value of the residue. For all of them an experimental error of 0.02 ml is applied with respect to the measurement (due to the systematic error of the balance, which has an accuracy of the centigram), but given the relative randomness of the above definitions, consider a real accuracy of an order of magnitude less (i.e. 0.2 ml)
+
In the following table are listed only the value of the residue. For all of them an experimental error of 0.02 ml is applied with respect to the measurement (due to the systematic error of the balance, which has an accuracy of the centigram), but given the relative arbitrariness of the above definitions, consider a real accuracy of an order of magnitude less (i.e. 0.2 ml)  
    
<center>
 
<center>
Riga 24: Riga 28:  
! rowspan="2" widht="15%"|Bottle  
 
! rowspan="2" widht="15%"|Bottle  
 
! rowspan="2" widht="5%"|total
 
! rowspan="2" widht="5%"|total
 +
! rowspan="2" widht="5%"| link
 
! colspan="4"| [[Pelikan 140]]
 
! colspan="4"| [[Pelikan 140]]
 
! colspan="4"| [[Duofold]]
 
! colspan="4"| [[Duofold]]
Riga 36: Riga 41:  
!widht="10%"|'''acrobatic'''
 
!widht="10%"|'''acrobatic'''
 
|-
 
|-
| Pelikan 4001|| 30 ml || 6,42 ml || 2,51 ml || 1,30 ml || 0,56 ml || 12,16 ml || 6.72 ml || 2,58 ml || 0,77 ml
+
| Pelikan 4001|| 30 ml || [https://forum.fountainpen.it/viewtopic.php?f=12&t=20857]
 +
| 6,42 ml || 2,51 ml || 1,30 ml || 0,56 ml || 12,16 ml || 6.72 ml || 2,58 ml || 0,77 ml
 +
|-
 +
| Montblanc (old)|| 50 ml || [https://forum.fountainpen.it/viewtopic.php?f=12&t=21091]
 +
| 21,27 ml || -- || 1,63 ml || 0,27 ml || 23,33 ml || -- || 2,36 ml || 0,84 ml
 +
|-
 +
| Visconti (old)|| 75 ml || [https://forum.fountainpen.it/viewtopic.php?f=12&t=21962]
 +
| 2,17 ml || 2,17 ml || 2,17 ml || 0,63 ml || 2,62 ml || 2,62 ml || 2,62 ml || 0,46 ml  
 
|-
 
|-
 
|}
 
|}
 
</center>
 
</center>
   −
{{CategorizeArticle|Principianti}}
+
{{CategorizeArticle|Principianti|Misure}}

Menu di navigazione